Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Детали продукта:
Место происхождения: СИАНЬ Шаньси
Фирменное наименование: XZH TEST
Сертификация: ISO/CE
Номер модели: XHGG501C
Подробная информация
Место происхождения:
СИАНЬ Шаньси
Фирменное наименование:
XZH TEST
Сертификация:
ISO/CE
Номер модели:
XHGG501C
Выделить:

High Light

Выделить:

Rough Fault Distance Cable Fault Locator

,

Low Voltage TDR Cable Tester

,

TDR Technology Cable Fault Detector

Trading Information
Количество мин заказа:
1 комплект
Упаковывая детали:
Деревянная упаковка
Время доставки:
5-8 рабочих дней
Условия оплаты:
Т/Т
Поставка способности:
3000единиц/год
Характер продукции
XHGG501C LV TDR Cable Fault Locator
The LV TDR cable fault locator provides rough fault distance measurement for low voltage cables, enabling quick identification of cable issues.
Key Features
  • Accurate rough fault distance measurement
  • Designed for low voltage cable systems
  • Time Domain Reflectometry (TDR) technology
  • Quick fault identification capability
Pulse width 0.2uS/2uS
minimum resolution 1.0M
Test blind spot ≤35m
Distance range ≥16km


Regarding waveforms


1. Standard waveform for open circuit fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 0

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (but can also be negative); at time t2, the reflected pulse waveform from the intermediate joint in the cable (reflected waves from joints are generally of the same polarity, but this depends on the joint structure); at time t3, the reflected pulse waveform from an open-circuit fault is positive and of the same polarity (the polarity of the fault waveform is the same as the polarity of the pulse wave generated by the instrument); at time t4, the secondary reflected pulse waveform from the open-circuit fault. Due to pulse attenuation, the secondary reflected wave at time t4 has a smaller amplitude than the primary reflected wave at time t3. The distance S from the fault point to the measuring end is... In actual operation, by moving the cursor, the instrument will automatically display and calculate the distance to the fault point.


2. Standard waveform for low impedance fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 1

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (or negative); at time t2, the reflected waveform from the intermediate joint in the cable is shown; at time t3, the reflected waveform from the low-resistance fault point is negative, representing a reflection with opposite polarity (opposite to the pulse waveform generated by the instrument); at time t4, the reflected waveform from the cable terminal is shown. The distance from the fault point to the measuring end is also considered.

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 2